※各データは多数溶解ポットの平均値です。
λ(nm) | T (%) | τ | OD | nm | km | |
---|---|---|---|---|---|---|
◆<指定波長> | 500 | 90.9 | 0.987 | 0.04 | 1.507 | 4.828E-07 |
▲<透過率50%> | 426.4 | 50.0 | 0.544 | 0.30 | 1.515 | 1.885E-05 |
d線(587.56nm) | 587.56 | 90.0 | 0.975 | 0.05 | 1.503 | 1.060E-06 |
e線(546.07nm) | 546.07 | 91.1 | 0.988 | 0.04 | 1.505 | 4.880E-07 |
【記号の意味】 | λ(nm) :波長 T (%) :透過率 | τ :内部透過率 OD :光学密度 | nm :屈折率 km :消衰係数 |
---|
λ(nm) | T (%) | τ | OD | nm | km |
---|---|---|---|---|---|
300 | 2.4E-02 | 2.6E-04 | 3.62 | 1.536 | 1.791E-04 |
310 | 5.5E-03 | 6.0E-05 | 4.26 | 1.527 | 2.179E-04 |
320 | 9.3E-03 | 1.0E-04 | 4.03 | 1.520 | 2.129E-04 |
330 | 1.7E-02 | 1.9E-04 | 3.77 | 1.527 | 2.049E-04 |
340 | 1.1E-02 | 1.3E-04 | 3.94 | 1.529 | 2.210E-04 |
350 | 2.1E-02 | 2.3E-04 | 3.67 | 1.527 | 2.117E-04 |
360 | 5.9E-03 | 6.4E-05 | 4.23 | 1.525 | 2.515E-04 |
370 | 5.5E-03 | 6.0E-05 | 4.26 | 1.524 | 2.601E-04 |
380 | 1.1E-02 | 1.2E-04 | 3.95 | 1.518 | 2.479E-04 |
390 | 2.3E-02 | 2.5E-04 | 3.64 | 1.519 | 2.339E-04 |
400 | 4.9E-02 | 0.001 | 3.31 | 1.516 | 2.180E-04 |
410 | 0.1 | 0.001 | 3.04 | 1.515 | 2.052E-04 |
420 | 5.5 | 0.060 | 1.26 | 1.516 | 8.539E-05 |
430 | 74.5 | 0.810 | 0.13 | 1.512 | 6.565E-06 |
440 | 88.4 | 0.961 | 0.05 | 1.513 | 1.262E-06 |
450 | 89.8 | 0.976 | 0.05 | 1.512 | 7.831E-07 |
460 | 90.1 | 0.979 | 0.05 | 1.511 | 7.150E-07 |
470 | 90.2 | 0.980 | 0.04 | 1.510 | 7.005E-07 |
480 | 90.7 | 0.985 | 0.04 | 1.509 | 5.410E-07 |
490 | 90.6 | 0.984 | 0.04 | 1.508 | 5.716E-07 |
500 | 90.9 | 0.987 | 0.04 | 1.507 | 4.828E-07 |
510 | 91.1 | 0.988 | 0.04 | 1.506 | 4.315E-07 |
520 | 91.1 | 0.989 | 0.04 | 1.506 | 4.199E-07 |
530 | 91.1 | 0.989 | 0.04 | 1.506 | 4.264E-07 |
540 | 90.9 | 0.986 | 0.04 | 1.505 | 5.457E-07 |
550 | 90.9 | 0.986 | 0.04 | 1.505 | 5.722E-07 |
560 | 90.7 | 0.984 | 0.04 | 1.504 | 6.564E-07 |
570 | 90.6 | 0.982 | 0.04 | 1.503 | 7.344E-07 |
580 | 90.2 | 0.978 | 0.04 | 1.503 | 9.247E-07 |
590 | 89.9 | 0.975 | 0.05 | 1.503 | 1.073E-06 |
600 | 89.7 | 0.972 | 0.05 | 1.502 | 1.234E-06 |
610 | 89.5 | 0.970 | 0.05 | 1.501 | 1.332E-06 |
620 | 89.2 | 0.967 | 0.05 | 1.501 | 1.513E-06 |
630 | 88.8 | 0.962 | 0.05 | 1.501 | 1.760E-06 |
640 | 88.7 | 0.961 | 0.05 | 1.501 | 1.850E-06 |
650 | 88.5 | 0.959 | 0.05 | 1.500 | 1.986E-06 |
660 | 87.9 | 0.952 | 0.06 | 1.500 | 2.339E-06 |
670 | 87.6 | 0.949 | 0.06 | 1.500 | 2.535E-06 |
680 | 87.4 | 0.947 | 0.06 | 1.500 | 2.657E-06 |
690 | 86.9 | 0.941 | 0.06 | 1.500 | 3.014E-06 |
700 | 86.6 | 0.938 | 0.06 | 1.499 | 3.258E-06 |
710 | 86.4 | 0.936 | 0.06 | 1.499 | 3.411E-06 |
720 | 86.1 | 0.933 | 0.06 | 1.499 | 3.604E-06 |
730 | 85.9 | 0.931 | 0.07 | 1.499 | 3.793E-06 |
740 | 85.6 | 0.927 | 0.07 | 1.498 | 4.056E-06 |
750 | 85.6 | 0.927 | 0.07 | 1.498 | 4.114E-06 |
760 | 85.5 | 0.926 | 0.07 | 1.498 | 4.211E-06 |
770 | 85.4 | 0.925 | 0.07 | 1.498 | 4.321E-06 |
780 | 85.4 | 0.925 | 0.07 | 1.498 | 4.429E-06 |
790 | 85.2 | 0.923 | 0.07 | 1.498 | 4.563E-06 |
800 | 85.7 | 0.929 | 0.07 | 1.498 | 4.284E-06 |
850 | 85.4 | 0.924 | 0.07 | 1.496 | 4.828E-06 |
900 | 86.3 | 0.935 | 0.06 | 1.498 | 4.381E-06 |
950 | 86.9 | 0.941 | 0.06 | 1.497 | 4.166E-06 |
1000 | 87.7 | 0.950 | 0.06 | 1.497 | 3.748E-06 |
1050 | 88.3 | 0.955 | 0.05 | 1.494 | 3.492E-06 |
1100 | 89.2 | 0.965 | 0.05 | 1.493 | 2.833E-06 |
1150 | 89.5 | 0.968 | 0.05 | 1.494 | 2.684E-06 |
1200 | 90.1 | 0.973 | 0.05 | 1.491 | 2.334E-06 |
1250 | 90.4 | 0.977 | 0.04 | 1.492 | 2.115E-06 |
1300 | 90.8 | 0.982 | 0.04 | 1.492 | 1.721E-06 |
1350 | 91.3 | 0.987 | 0.04 | 1.492 | 1.290E-06 |
1400 | 90.8 | 0.981 | 0.04 | 1.490 | 1.963E-06 |
1450 | 91.1 | 0.984 | 0.04 | 1.488 | 1.650E-06 |
1500 | 91.5 | 0.988 | 0.04 | 1.486 | 1.336E-06 |
データ作成には日立分光光度計U-4100を使用
2009年12月04日更新
2009年12月04日更新